2.
J Pers Med ; 12(7)2022 Jul 05.
Article Dans Anglais | MEDLINE | ID: covidwho-1917579

Résumé

Kidney transplant recipients (KTRs) displays marked inter-individual variations in magnitude of immune responses to anti-SARS-CoV-2 vaccination. The aim of this large single-center study was to identify the predictive factors for serological response to the mRNA-1273 vaccine in KTRs. We also devised a score to optimize prediction with the goal of implementing a personalized vaccination strategy. The study population consisted of 564 KTRs who received at least two doses of the mRNA-1273 vaccine. Anti-RBD IgG titers were quantified one month after each vaccine dose and until six months thereafter. A third dose vaccine was given when the antibody titer after the second dose was <143 BAU/mL. A score to optimize prediction of vaccine response was devised using the independent predictors identified in multivariate analysis. The seropositivity rate after the second dose was 46.6% and 22.2% of participants were classified as good responders (titers ≥ 143 BAU/mL). On analyzing the 477 patients for whom serology testing was available after the second or third dose, the global seropositivity rate was 69% (good responders: 46.3%). Immunosuppressive drugs, graft function, age, interval from transplantation, body mass index, and sex were associated with vaccine response. The devised score was strongly associated with the seropositivity rate (AUC = 0.752, p < 0.0001) and the occurrence of a good antibody response (AUC = 0.785, p < 0.0001). Notably, antibody titers declined over time both after the second and third vaccine doses. In summary, a high burden of comorbidities and immunosuppression was correlated with a weaker antibody response. A fourth vaccine dose and/or pre-exposure prophylaxis with monoclonal antibodies should be considered for KTRs who remain unprotected.

3.
Am J Transplant ; 22(11): 2675-2681, 2022 Nov.
Article Dans Anglais | MEDLINE | ID: covidwho-1895939

Résumé

The cilgavimab-tixagevimab combination retains a partial in vitro neutralizing activity against the current SARS-CoV-2 variants of concern (omicron BA.1, BA.1.1, and BA.2). Here, we examined whether preexposure prophylaxis with cilgavimab-tixagevimab can effectively protect kidney transplant recipients (KTRs) against the omicron variant. Of the 416 KTRs who received intramuscular prophylactic injections of 150 mg tixagevimab and 150 mg cilgavimab, 39 (9.4%) developed COVID-19. With the exception of one case, all patients were symptomatic. Hospitalization and admission to an intensive care unit were required for 14 (35.9%) and three patients (7.7%), respectively. Two KTRs died of COVID-19-related acute respiratory distress syndrome. SARS-CoV-2 sequencing was carried out in 15 cases (BA.1, n = 5; BA.1.1, n = 9; BA.2, n = 1). Viral neutralizing activity of the serum against the BA.1 variant was negative in the 12 tested patients, suggesting that this prophylactic strategy does not provide sufficient protection against this variant of concern. In summary, preexposure prophylaxis with cilgavimab-tixagevimab at the dose of 150 mg of each antibody does not adequately protect KTRs against omicron. Further clarification of the optimal dosing can assist in our understanding of how best to harness its protective potential.


Sujets)
COVID-19 , Transplantation rénale , Humains , SARS-CoV-2 , Transplantation rénale/effets indésirables , Anticorps neutralisants , Anticorps antiviraux
7.
Am J Transplant ; 20(11): 3162-3172, 2020 11.
Article Dans Anglais | MEDLINE | ID: covidwho-703597

Résumé

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has spread widely, causing coronavirus disease 2019 (COVID-19) and significant mortality. However, data on viral loads and antibody kinetics in immunocompromised populations are lacking. We aimed to determine nasopharyngeal and plasma viral loads via reverse transcription-polymerase chain reaction and SARS-CoV-2 serology via enzyme-linked immunosorbent assay and study their association with severe forms of COVID-19 and death in kidney transplant recipients. In this study, we examined hospitalized kidney transplant recipients with nonsevere (n = 21) and severe (n = 19) COVID-19. SARS-CoV-2 nasopharyngeal and plasma viral load and serological response were evaluated based on outcomes and disease severity. Ten recipients (25%) displayed persistent viral shedding 30 days after symptom onset. The SARS-CoV-2 viral load of the upper respiratory tract was not associated with severe COVID-19, whereas the plasma viral load was associated with COVID-19 severity (P = .010) and mortality (P = .010). All patients harbored antibodies during the second week after symptom onset that persisted for 2 months. We conclude that plasma viral load is associated with COVID-19 morbidity and mortality, whereas nasopharyngeal viral load is not. SARS-CoV-2 shedding is prolonged in kidney transplant recipients and the humoral response to SARS-CoV-2 does not show significant impairment in this series of transplant recipients.


Sujets)
Anticorps antiviraux/immunologie , COVID-19/virologie , Transplantation rénale , Pandémies , SARS-CoV-2/immunologie , Charge virale , Sujet âgé , COVID-19/épidémiologie , Comorbidité , Test ELISA , Femelle , France/épidémiologie , Humains , Mâle , Adulte d'âge moyen , Partie nasale du pharynx/virologie , Taux de survie/tendances